BTH-TGA601 thermogravimetric analyzer
- First, instrument description:
Thermogravimetric analysis (TG, TGA) is in the process of heating, constant temperature or cooling, observing the quality of the sample with the change of temperature or time, the purpose is to study the thermal stability and composition of the material. Widely used in plastics, rubber, coatings, drugs, catalysts, inorganic materials, metal materials and composite materials and other fields of research and development, process optimization and quality control. The following properties of materials are measured and studied: thermal stability, decomposition process, adsorption and desorption, oxidation and reduction, quantitative analysis of components, effects of additives and fillers, moisture and volatiles, reaction kinetics.
- Second, the main characteristics:
- Imported balance, balance with internal calibration function, with better accuracy and repeatability.
- Imported alloy sensor, more corrosion resistance, oxidation resistance, high sensor sensitivity.
- The furnace body heating is wound with precious metal alloy wire, which reduces interference and is more resistant to high temperature.
- Perfect atmosphere control system, software setting automatic switching, data directly recorded in the database.
- Cortex-M3 core ARM controller is adopted, which is faster in calculation and processing and more accurate in temperature control.
- USB bidirectional communication, fully realize intelligent operation.
- Using 7 inch 24bit color LCD touch screen, real-time display of instrument status and data.
- The upper open cover structure, easy to operate. It is difficult to move up the furnace body to put samples, which is easy to cause damage to the sample rod.
- Automatically generate test report and print it. Software built-in test record, data processing and report format, automatically issue the test report
- Third, technical parameters:
- Temperature range: room temperature ~1250℃
- Temperature resolution: 0.01℃
- Temperature fluctuation: ±0.1℃
- Heating rate: 0.1~100℃/min
- Temperature control mode: temperature rise, constant temperature
- Measuring range of balance: 0.01mg ~ 2g
- Resolution: 0.01mg
- Constant temperature time: 0 ~ 300min arbitrary setting
- Display mode: Chinese characters large screen LCD display
- Atmosphere: inert, oxidizing, reducing, static, dynamic
- Atmosphere device: built-in gas flow meter, including two gas switching and flow size control
- Software: Intelligent software can automatically record TG curve for data processing and print experimental reports
- Data interface: standard USB interface, special software (software upgrade from time to time)
- Power: AC220V 50Hz
- Fourth, instrument configuration:
Serial number |
Contents |
Quantity (table) |
remark |
1 |
TGA-601 Thermogravimetric analyzer mainframe |
One |
|
2 |
Accompanying software USB flash drive |
1 sheet |
|
3 |
Data cable |
2 |
|
4 |
Power cord |
1 |
|
5 |
Ceramic Crucible |
100 pieces |
reusable |
6 |
Accessory tools |
A set |
|
7 |
Standard Substances |
1 serving |
|
8 |
Instructions |
1 copy |
|
9 |
Certificate of Conformity |
1 copy |
|
10 |
Warranty card |
1 copy |
|
Note: Your company needs configuration: nitrogen cylinder, oxygen cylinder and matching pressure relief meter