亚洲精品乱码久久久久久久久久久久,成全视频观看免费高清动漫,亚洲精品国产电影,公粗挺进了我的密道在线播放贝壳

Hotline
400-850-9596

Product current:home > Product > Low gentleness meter
Low gentleness meter

Low gentleness meter

 

First, overview

Building waterproof coil low gentleness tester is according to the national building waterproof coil test method GB/T328.14-2007 and developed, is the waterproof coil low gentleness test method from the original manual test to mechanical test experimental instrument. It consists of two parts: low gentleness test machine and control instrument. Low gentleness test machine is made of 304 stainless steel, suitable for working in the temperature of -40℃ to 50℃ environment, the power is driven by permanent magnet synchronous motor, has the characteristics of high reliability long service life, stable speed, low noise, with efficient transmission mechanism, making the equipment has the characteristics of delicate and lightweight, easy to operate, the controller adopts button box controller, It has the characteristics of simple and reliable operation, low failure rate, and accurately control the testing machine to work. The equipment is a necessary instrument for the upgrading of low gentleness test in coil waterproofing industry.

Second, the main functions and technical indicators

1, Input power, power: 220V, 110 (W)

2, test sample thickness: 1-5 (mm)

3, the maximum number of test standard samples: 10 (standard sample size is 150*25 mm)

4, test rate: 360±40 (mm/min)

5, test temperature range: -40 ~ 50 (℃)

6, with a diameter of 20, 30, 50 two kinds of roller diameter test mode

7, the testing machine can be lifted up and down in the groove

Third, the use of

1, the working principle diagram:

  1. Operation steps

Experiment preparation

  1. Place the low gentleness tester in the cryogenic freezer. The control box is placed outside, and the two are connected by a connecting cable.
    2, first put the cooling tank into the low temperature box plus freezing liquid "with propylene glycol/aqueous solution (volume ratio l: 1) below -25℃ or below -20℃ ethanol/water mixture (volume ratio 2: 1) Freeze to the required temperature, and then adjust the distance between the two circular shafts of the flexibility meter according to the specimen, that is, the diameter of the bending crankshaft +2mm+ twice the thickness of the specimen, press the rise key to raise the bending crankshaft to parallel with the two fixed shafts, insert the specimen plate selected according to the thickness of the coil between the bending crankshaft and the fixed shaft, and move the two fixed shafts to the specimen plate without gap after tightening the screws at both ends. Press the down key to make the bending shaft return, place the specimen on the bending shaft and bracket in the cooled low temperature water tank, and the upper end of the specimen is 10mm below the chilled liquid level.

3, the controller power on, according to the standard setting of the temperature, time, the method is to press the set key, the time window digit begins to blink, press the rise key or down key to adjust, press the set key shift press rise or fall adjustment, press the stop key to exit after the setting. At this time, the temperature display is the temperature in the coolant, press the start key when the temperature reaches the set temperature, the time begins to time, when the set time is reached, the bending crankshaft against the specimen begins to rise at the speed of 360 mm/min, when the bending crankshaft stops, the test is completed, check whether the specimen has cracks, press the falling key to bend the crankshaft down to the starting point.

 

 

the previous:Differential scanning calorimeter next:Pipe scriber
Go top